AvailableAir handling

Air handling units

Application-specific AHUs for pharmaceutical, industrial and commercial facilities, configured around airflow, filtration, cooling, humidity and room pressure requirements.

Industrial air handling plant and ductwork

Air that is filtered, conditioned and delivered on specification.

An air handling unit takes in outdoor and return air, filters it, cools or heats it, controls its moisture and delivers it to the space at the required volume and pressure. In controlled environments the AHU is the heart of how temperature, humidity, cleanliness and room pressure are held.

Air handling unit, operating principle Outdoor and return air are mixed, filtered in stages, cooled below dew point to remove moisture, reheated, and delivered by the supply fan through terminal HEPA filters to a room held at positive pressure. Outdoor air Return air from the room Room + Mixing Filtration Cooling Reheat Supply fan Discharge

Follow the air

Air changes state at every section. Select a section to see what it does to the air.

  • Outdoor air
  • Return air
  • Dust captured by filters
  • Cooled and dehumidified
  • Reheated supply
Illustration shows a typical controlled-environment AHU arrangement. Sections are selected per project.

Operating principle

  1. Mix

    Outdoor air and return air are mixed through dampers in the proportion the space needs.

  2. Filter

    Pre-filters and fine filters remove particles in stages to protect the coils and the space.

  3. Cool and dehumidify

    The cooling coil lowers air temperature below its dew point, so moisture condenses and drains away.

  4. Reheat

    Where humidity control requires it, a reheat coil brings the air back up to the supply temperature.

  5. Supply under pressure

    The supply fan delivers air to the space. Terminal HEPA filters and room pressure control are added where the application calls for them.

Specifications

Reference data and the parameters we size for each project.

ParameterProject-specific units
Casing constructionDouble-skin panels, specification per project
Filtration stagesStaged to the application
CoilsChilled water, DX or hot water, per project
Fan typeSelected for duty and efficiency
Controls interfaceTo suit the building management system
StatusSupplied to project requirements
Project-specific selections are confirmed in the technical proposal for each enquiry.

Airflow and pressure

Air change rates, room pressure relationships and system resistance set the fan duty.

Psychrometrics

Coil selection follows the full design condition — sensible and latent load — not just a tonnage figure.

Hygienic design

Smooth internals, sloped drain pans and full access are how an AHU stays clean in service.

Applications

  • Pharmaceutical manufacturing and packaging areas
  • Controlled environments with pressure cascades
  • Industrial production halls and process areas
  • Commercial buildings and facilities

Configuration options

  • Fresh-air, recirculation or mixed-air configurations
  • Staged filtration, with terminal HEPA where specified
  • Cooling, heating, reheat and humidity-control sections
  • Hygienic internal finishes and cleanable drain pans
  • Access doors, inspection windows and lighting for servicing
  • Energy recovery sections where the duty justifies them

Photographs

Technical documents

Drawings and datasheets are issued against your enquiry so they reflect your duty.

Specify your air handling units.

Send us the duty, site conditions and any drawings. We will review the application and respond with a technical proposal.